KSL – Sensorless Brushless Motor Controller (12V-72V) (100-500A)

Applicable to sensorless BLDC motors for fans, water pump, air-conditioning, compressor, etc.

Share

$119.00$379.00

Additional information

Weight 4.20 lbs
Description
ModelNominal VoltageMax Operating VoltagePeak Current 1 MinuteContinuous Current
KSL2410012V-24V35V100A50A
KSL2420012V-24V35V200A100A
KSL2430012V-24V35V300A150A
KSL2440012V-24V35V400A200A
KSL4810024V-48V62V100A50A
KSL4820024V-48V62V200A100A
KSL4830024V-48V62V300A150A
KSL7210024V-72V86V100A50A
KSL7220024V-72V86V200A100A
KSL7230024V-72V86V300A150A
KSL72400E24V-72V86V400A200A
KSL72500E24V-72V86V500A250A
Kelly KSL Sensorless Brushless DC Motor Controller

Features:

  • Intelligence with powerful microprocessor.
  • Synchronous rectification, ultra low drop and fast PWM to achieve very high efficiency.
  • Current limit.
  • Battery current limiting available. Doesn’t affect taking off performance.
  • Low EMC.
  • LED fault code.
  • Battery protection: current cutback, warning and shutdown at configurable high and low battery voltage.
  • Rugged aluminum housing for maximum heat dissipation and harsh environment.
  • Rugged high current terminals, and rugged aviation connectors for small signal.
  • Thermal protection: current cut back, warning and shutdown on high temperature.
  • Current multiplication: Take less current from battery, output more current to motor.
  • Easy installation: 3-wire potentiometer will work.
  • Stuck Rotor protection.
  • Up to 17000 electric RPM. (Electric RPM=mechanical RPM * motor poles)
  • Standard PC/Laptop computer to do programming. No special tools needed.
  • User program provided. Easy to use. No cost to customers.

General Specifications:

  • Frequency of Operation: 16.6kHz.
  • Standby Battery Current: < 2mA.
  • 5V Sensor Supply Current: 40mA.
  • Controller supply voltage range, PWR, 18V-90V.
  • Configurable battery voltage range, B+. Max operating range: 18V-90V
  • Analog Throttle Input: 0-5 Volts. Producing 0-5V signal with 3-wire pot.
  • Reverse Alarm, Meter, Main Contactor Coil Driver: <200mA.( NA*)
  • Full Power Operating Temperature Range: 0℃ to 50℃ (controller case temperature).
  • Operating Temperature Range: -30℃ to 90℃, 100℃shutdown (controller case temperature).
  • Motor Current Limit, boost current: 100A
  • Motor Current Limit, continuous: 50A
  • Max Battery Current: Configurable.

Downloads:

Kelly KSL Controllers User Manual

Kelly KSL Configuration Program